Frequency Conversion Precision Air Conditioning For Data Center

Hefei Coolnet power Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

Frequency Conversion Precision Air Conditioning For Data Center

Brand Name : Coolent

Model Number : CYAT40D/U

Certification : ISO/CE

Place of Origin : China

MOQ : 1

Price : to be Negotiated

Payment Terms : T/T

Supply Ability : 1000/Month

Delivery Time : 4W

Packaging Details : WOODEN

cooling capacity : 70KW

Mounting : Floor Standing

Type : Close Control Unit ( air cooled )

Product name : Precision Air Conditioning

Refrigerant : R22(R407C/R410A)

Application : Computer Room,Printing factory/cinema/supper marekt/restaurant/Offfice/Kindergarten,Industrial,Heat recovery,adjust cold/heat/humidity

Power : 3N-380V-50Hz,220v/50hz/60hz

Airflow : Down Flow

Contact Now

Precision Air Conditioning Frequency Conversion Type For Date Center

Products Introduction

Precision air conditioning controls the ambient environment by providing constant temperature and humidity conditions to costly and sensitive sophisticated electronic equipments throughout the year. This is in contrast to normal air conditioning which provides only the cooling comfort to people sitting in a room.

CyberMasterTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMasterTM meets the cooling demand and reduce the PUE of the data center.

Benefits

Frequency Conversion Precision Air Conditioning For Data Center

Frequency Conversion Precision Air Conditioning For Data Center

Application Range

Frequency Conversion Precision Air Conditioning For Data Center
  • Computer room and data center
  • Switch room and mobile center station in telecommunication
  • High-tech environment and lab
  • Industrial automation control room and precision manufacturing workshop
  • Standard test room and calibration center
  • UPS and battery room
  • Test room in hospital
  • Biochemical culture chamber

Technical Features

High reliability

Providing Constant temperature & humidity, Cleanliness environment to ensure the main equipment run in good condition.

All-day running design can guarantee the main equipment safe operation.

All parts had passed severe test and confirmed stable and reliable before delivery.

High energy efficiency

Sensible heat ratio is up to 91%.

Compressor energy efficiency ratio is over 3.1, and chilled water cooled unit’s cooling energy efficiency is larger than 25.

The optimal and high efficiency compressor and fans.

“W/M” type evaporator with super large heat exchange area.

Independent air duct design can reduce air resistance significantly and minimize fans power.

Variable frequency design on ODU is more efficient and has longer working life.

Advanced control logic can effectively avoid competitive running and output cooling capacity according to actual cooling capacity demand.

Easy maintenance

Front panel maintenance: All maintenance work can be operated from front panel.

Air filter with metal frame: Cleanable repeatedly, low maintenance cost

Self-cleaning humidifier: lower maintenance work

Modular design with least spare parts

Pressure difference monitoring for air filters can detect whether air filters was blocked or not.

Multiple types

Wide capacity range: air cooled type(5kW~120kW),Water cooled type(5-120KW),chilled water cooled type(30kW~200kW).

Multiple cooling mode:air cooled, water cooled, glycol cooled, chilled water cooled(with single/dual coil), air cooled & chilled water cooled, air cooled & free cooling, Freon pump free cooling.

Multiple air supplying modes: cap tuyere mode, air duct mode, floorboard mode.

Multiple refrigerant types: R410A, R407C, R22.

Wide ambient air temperature rang: standard range(-20℃~50℃),low temperature range(-40℃~50℃).

Frequency Conversion Precision Air Conditioning For Data Center

Technical Parameters

Model: CYA T26D/U T31D/U T35D/U T41D/U T45D/U T50D/U T55D/U T61D/U T70D/U T76D/U T85D/U T90D/U T100D/U
Power Supply 380V 3Ph-50HZ
Air Discharge Upflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1) KW 26.9 31.9 35.9 41.9 45.3 50.5 55.4 61.4 70.5 76.2 85.5 90.8 102
Sensible KW 24.8 29.5 33.1 38.8 42.5 47.8 51.6 57.5 65.2 71.2 79.5 84.5 95.7
AEER W/W 3.6 3.6 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.6 3.6 3.6
Air Flow m3/h 8000 9500 10000 11500 13000 15500 16000 17500 18500 20500 22500 23500 24200
Compressor Hermetic scroll
Refrigerant R407C
Compressor quantity PC 2 2 2 2 2 2 2 2 2 2 2 2 2
Fan Section Centrifugal fan (Optional EC)
Fan quantity PC 2 2 2 2 2 2 2 2 2 3 3 3 3
Rated current A 4.3 4.3 4.3 4.4 4.4 4.4 5 5.2 5.2 6.5 16.5 16.5 16.5
Rated power W 1600 1600 1800 1800 2000 2000 3000 3300 3900 3900 5400 6300 6300
Total heating capacity KW 6 6 6 9 9 9 9 9 9 12 12 12 12
Material PTC
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 13 13 13 13 13 13 13 13 13
Rated Current A 6 6 6 6 15 15 15 15 15 15 15 15 15
Condenser Model 2*58 2*58 2*58 2*58 2*80 2*80 2*100 2*100 2*120 2*150 2*150 2*165 2*180

Certificates

Frequency Conversion Precision Air Conditioning For Data Center

Factory Details

Frequency Conversion Precision Air Conditioning For Data Center

Packing & Delivery

Frequency Conversion Precision Air Conditioning For Data Center

Case

Frequency Conversion Precision Air Conditioning For Data Center


Product Tags:

R22 precision air conditioning for data center

      

70KW precision air conditioning for data center

      

R22 70KW close control air conditioning

      